101. |
Double focussing section analysers offer better resolution than ICP spectrometry system.(a) True(b) FalseThis question was addressed to me in an international level competition.I need to ask this question from Inductively Coupled Plasma Mass Spectrometer topic in section Mass Spectrometer of Analytical Instrumentation |
Answer» Correct option is (a) True |
|
102. |
Which of the following is not a feature of quadrupole mass spectrometer?(a) Low cost(b) Light weight(c) Low speed electronic scanning(d) Simple in constructionThis question was posed to me in semester exam.The doubt is from Quadrupole Mass Spectrometer topic in chapter Mass Spectrometer of Analytical Instrumentation |
Answer» The correct choice is (c) LOW SPEED electronic scanning |
|
103. |
Which of the following is the least sensitive ion detector?(a) Faraday cup collector(b) Channeltron(c) Micro-channel plate(d) Electron multiplier transducerThe question was asked in quiz.I'd like to ask this question from Ion Transducers topic in chapter Mass Spectrometer of Analytical Instrumentation |
Answer» Correct choice is (a) Faraday cup collector |
|
104. |
Which of the following can be introduced into the ionization chamber directly?(a) Solid samples with low vapour pressure(b) Solid samples with high vapour pressure(c) Liquid samples with low density(d) Liquid samples with high densityThe question was posed to me in homework.I want to ask this question from Components of Mass Spectrometer in section Mass Spectrometer of Analytical Instrumentation |
Answer» The correct OPTION is (a) Solid samples with LOW vapour pressure |
|
105. |
In magnetic deflection mass spectrometer, in which of the following ways is acceleration applied to the direction of motion?(a) In random manner(b) Parallel to it(c) Perpendicular to it(d) Along itI got this question during an interview.This interesting question is from Magnetic Deflection Mass Spectrometer in portion Mass Spectrometer of Analytical Instrumentation |
Answer» Right option is (c) Perpendicular to it |
|
106. |
In mass spectrometer, the sample that has to be analysed is bombarded with which of the following?(a) Protons(b) Electrons(c) Neutrons(d) Alpha particlesThe question was asked in semester exam.My question is taken from Principle of operation of Mass Spectrometer in portion Mass Spectrometer of Analytical Instrumentation |
Answer» Right option is (b) Electrons |
|
107. |
Which of the following is not a component of mass spectrometer?(a) Inlet system(b) Sweep generator(c) Ion transducer(d) Mass analyserI had been asked this question during an internship interview.I'm obligated to ask this question of Components of Mass Spectrometer in division Mass Spectrometer of Analytical Instrumentation |
Answer» RIGHT answer is (B) Sweep GENERATOR The best I can explain: Sweep generator is not a COMPONENT of a mass spectrometer. It is a component of NMR spectrometer. |
|
108. |
In mass spectrometer, the ions are sorted out in which of the following ways?(a) By accelerating them through electric field(b) By accelerating them through magnetic field(c) By accelerating them through electric and magnetic field(d) By applying a high voltageThis question was addressed to me in an interview.I need to ask this question from Principle of operation of Mass Spectrometer in chapter Mass Spectrometer of Analytical Instrumentation |
Answer» Right option is (c) By ACCELERATING them through electric and magnetic field |
|
109. |
The most common type of ion detector found in ICP system is which of the following?(a) Faraday cup collector(b) Channeltron(c) Micro-channel plate(d) Flame ionization detectorThis question was addressed to me during an online interview.This intriguing question comes from Inductively Coupled Plasma Mass Spectrometer topic in division Mass Spectrometer of Analytical Instrumentation |
Answer» The correct option is (b) Channeltron |
|
110. |
In reverse-geometry mass spectrometer which of the following precedes the electric sector?(a) Nebulizer(b) Orifice(c) Magnetic sector(d) Mass spectrometerI got this question during an online exam.This interesting question is from Tandem Mass Spectroscopy in section Mass Spectrometer of Analytical Instrumentation |
Answer» Correct answer is (C) MAGNETIC sector |
|
111. |
Which of the following is not a type of ionisation?(a) Field ionisation(b) Spontaneous ionisation(c) Spark ionisation(d) Chemical ionisationThe question was asked in semester exam.Question is from Components of Mass Spectrometer topic in portion Mass Spectrometer of Analytical Instrumentation |
Answer» The correct answer is (b) SPONTANEOUS ionisation |
|
112. |
Ions flow is pumped into the vacuum system using which of the following?(a) Orifice(b) Nozzle(c) Venturi meter(d) Dall tubeThis question was addressed to me by my college director while I was bunking the class.This interesting question is from Inductively Coupled Plasma Mass Spectrometer in division Mass Spectrometer of Analytical Instrumentation |
Answer» CORRECT option is (a) Orifice To elaborate: IONS flow is pumped into the VACUUM system using orifice. It expands in the vacuum system. |
|
113. |
Atomisation or ionisation occurs at which of the following conditions?(a) Vacuum pressure(b) Atmospheric pressure(c) Low pressure(d) High pressureI had been asked this question in an international level competition.The origin of the question is Inductively Coupled Plasma Mass Spectrometer topic in chapter Mass Spectrometer of Analytical Instrumentation |
Answer» CORRECT choice is (d) HIGH pressure For explanation I would say: Atomization or ionisation occurs at ATMOSPHERIC pressure. The interface between the ICP and MS components are crucial in CREATING a VACUUM. |
|
114. |
Using an interface would reduce detection limit and sensitivity.(a) True(b) FalseI got this question during an internship interview.Asked question is from Liquid Chromatograph- Mass Spectrometer in chapter Mass Spectrometer of Analytical Instrumentation |
Answer» The correct choice is (a) True |
|
115. |
Which of the following is the disadvantage of gas chromatography?(a) It is not a good method(b) It cannot be used for qualitative analysis(c) It cannot be used for the separation of volatile components(d) It does not provide direct identificationI got this question in an online interview.My doubt is from Gas Chromatograph- Mass Spectrometer topic in division Mass Spectrometer of Analytical Instrumentation |
Answer» Correct choice is (d) It does not PROVIDE direct identification |
|
116. |
Which of the following is not an ion transducer or detector?(a) Faraday cup collector(b) Channeltron(c) Micro-channel plate(d) Flame ionization detectorThe question was posed to me in an online quiz.My question comes from Ion Transducers in section Mass Spectrometer of Analytical Instrumentation |
Answer» The correct answer is (d) Flame ionization DETECTOR |
|
117. |
If all the ions have the same kinetic energy how are their masses related to their velocities?(a) Mass and velocity are equal(b) Mass and velocity are not related(c) Mass and velocity are directly proportional(d) Mass and velocity are inversely proportionalThe question was asked in exam.My question is based upon Time of Flight Mass Spectrometer topic in section Mass Spectrometer of Analytical Instrumentation |
Answer» The correct answer is (d) Mass and VELOCITY are inversely proportional |
|
118. |
In pyrolysis spectrometry, heating is done until which of the following is reached?(a) Curie point(b) Boiling point(c) Until production of superheated vapour(d) Until 100^oCThis question was posed to me by my college professor while I was bunking the class.This interesting question is from Quadrupole Mass Spectrometer topic in section Mass Spectrometer of Analytical Instrumentation |
Answer» RIGHT ANSWER is (a) Curie point Best explanation: In PYROLYSIS spectrometry, heating is done until curie point is reached. At this point, MAGNETIC permeability drops abruptly. |
|
119. |
In mass spectrometer, the sample gas is introduced into the highly evacuated spectrometer tube and it is ionised by electron beam.(a) True(b) FalseThis question was addressed to me at a job interview.I would like to ask this question from Principle of operation of Mass Spectrometer topic in division Mass Spectrometer of Analytical Instrumentation |
Answer» Correct option is (a) True |
|
120. |
Which of the following separate the ions according to their mass-to-charge?(a) Ion source(b) Detector(c) Magnetic sector(d) Electric sectorI have been asked this question in unit test.This intriguing question originated from Magnetic Deflection Mass Spectrometer topic in portion Mass Spectrometer of Analytical Instrumentation |
Answer» RIGHT answer is (c) MAGNETIC SECTOR The explanation: Magnetic sector will separate the IONS according to their mass-to-charge. The magnet will decide the mass to charge ratio. |
|
121. |
Under which of the following temperatures is the ionisation chamber maintained?(a) 100^oC(b) 200^oC(c) 300^oC(d) 400^oCThe question was posed to me in semester exam.My enquiry is from Components of Mass Spectrometer topic in portion Mass Spectrometer of Analytical Instrumentation |
Answer» Right ANSWER is (B) 200^oC |
|
122. |
The procedure for mass spectroscopy starts with which of the following processes?(a) The sample is bombarded by electron beam(b) The ions are separated by passing them into electric and magnetic field(c) The sample is converted into gaseous state(d) The ions are detectedI have been asked this question in an online quiz.This is a very interesting question from Principle of operation of Mass Spectrometer topic in division Mass Spectrometer of Analytical Instrumentation |
Answer» Correct option is (c) The SAMPLE is converted into gaseous state |
|
123. |
No two molecules will be fragmented and ionized in exactly the same manner.(a) True(b) FalseThe question was asked in an interview for internship.I need to ask this question from Principle of operation of Mass Spectrometer topic in division Mass Spectrometer of Analytical Instrumentation |
Answer» CORRECT choice is (a) True For EXPLANATION: No two molecules will be FRAGMENTED and ionized in exactly the same manner. This is how different molecules are identified in a complex mixture. |
|
124. |
What does the acronym ‘MIKES’ stand for?(a) Mass-analysed ion kinetic energy spectrometer(b) Mass-based induced kinetic energy spectrometer(c) Mass invasive kinetic electric spectrometer(d) Mass-analyser in a kinetic energy-type spectrometerThis question was addressed to me in an online interview.My question is taken from Tandem Mass Spectroscopy in portion Mass Spectrometer of Analytical Instrumentation |
Answer» The correct answer is (a) Mass-analysed ion kinetic energy SPECTROMETER |
|
125. |
In MIKES experiments which of the following are measured?(a) Product ions(b) Product ion kinetic energies(c) Product ions mass to charge ratio(d) Product ions massesThis question was posed to me during an internship interview.My doubt stems from Tandem Mass Spectroscopy in chapter Mass Spectrometer of Analytical Instrumentation |
Answer» The CORRECT answer is (b) Product ION kinetic ENERGIES |
|
126. |
Which of the following is used to separate a single mass that is characteristic of a given analyte in a mixture?(a) First mass spectrometer(b) Second mass spectrometer(c) Filter(d) PrecursorThis question was posed to me in semester exam.My question comes from Tandem Mass Spectroscopy in section Mass Spectrometer of Analytical Instrumentation |
Answer» The CORRECT answer is (a) First mass spectrometer |
|
127. |
ICP is used to analyse samples in which of the following states?(a) Solids(b) Liquids(c) Gases(d) Solids and liquidsThis question was addressed to me in final exam.This intriguing question originated from Inductively Coupled Plasma Mass Spectrometer topic in chapter Mass Spectrometer of Analytical Instrumentation |
Answer» Right answer is (d) Solids and liquids |
|
128. |
In quadrupole mass spectrometer, the ratio u/v is mass dependent, where ‘u’ is the DC voltage and ‘v’ is the peak amplitude.(a) True(b) FalseI had been asked this question in an interview for job.I want to ask this question from Quadrupole Mass Spectrometer topic in section Mass Spectrometer of Analytical Instrumentation |
Answer» Correct answer is (b) False |
|
129. |
Which of the following is not the characteristic of ICP spectrometer?(a) Easy sample introduction(b) It can trace multiple elements(c) High detection limits(d) AccurateThis question was posed to me by my college director while I was bunking the class.My question is from Inductively Coupled Plasma Mass Spectrometer in division Mass Spectrometer of Analytical Instrumentation |
Answer» The correct CHOICE is (c) HIGH detection limits |
|
130. |
Which of the following is the heart of quadrupole instrument?(a) Electrodes(b) Choke(c) DC potential(d) DetectorThe question was asked in examination.The query is from Quadrupole Mass Spectrometer topic in division Mass Spectrometer of Analytical Instrumentation |
Answer» The CORRECT choice is (a) Electrodes |
|
131. |
Which of the following statements is not true about mass spectrometry?(a) Impurities of masses different from the one being analysed interferes with the result(b) It has great sensitivity(c) It is suitable for data storage(d) It is suitable for library retrievalI had been asked this question at a job interview.This intriguing question comes from Principle of operation of Mass Spectrometer topic in section Mass Spectrometer of Analytical Instrumentation |
Answer» Right choice is (a) Impurities of masses different from the one being analysed interferes with the RESULT |
|
132. |
Solid samples are introduced into the ICP spectrometer using which of the following?(a) Nebulizer(b) Curvette having glass windows(c) Probe(d) Laser ablation systemI had been asked this question in an interview for internship.I'd like to ask this question from Inductively Coupled Plasma Mass Spectrometer in chapter Mass Spectrometer of Analytical Instrumentation |
Answer» The CORRECT answer is (d) Laser ablation system |
|