| 51. |
What is used as a photodetector in pulse oximetry?(a) Phototransistor(b) Solar cell(c) Photodiode(d) Photographic platesI have been asked this question in quiz.My enquiry is from Pulse Oximeter topic in chapter Oximeters of Biomedical Instrumentation |
|
Answer» Correct answer is (c) Photodiode |
|
| 52. |
The toco-transducers are temperature sensitive.(a) True(b) FalseI had been asked this question in an online quiz.This interesting question is from Ear Oximeter in section Oximeters of Biomedical Instrumentation |
|
Answer» Right OPTION is (b) FALSE |
|
| 53. |
Which transducer is arranged in the shape of a clover leaf so that it provides a large area of illumination?(a) piezo-electric(b) ultrasonic(c) array(d) pressureThis question was addressed to me during an interview.My question is from Oximeters in chapter Oximeters of Biomedical Instrumentation |
|
Answer» The correct option is (b) ultrasonic |
|
| 54. |
What is the ratio of the sampling time to wash time?(a) 1:2(b) 3:1(c) 2:1(d) 1:3I had been asked this question during an interview for a job.My doubt is from Skin Reflectance Oximeters topic in chapter Oximeters of Biomedical Instrumentation |
|
Answer» RIGHT choice is (c) 2:1 Easiest explanation: Between each sampling, the crook ENTERS a receptacle of WATER or other suitable wash fluid, to REDUCE cross-contamination of one sample with another. The ratio of sampling time to wash time is NORMALLY 2:1. |
|
| 55. |
The normal red cell lasts approximately ______ before it is destroyed.(a) 90 days(b) 210 days(c) 120 days(d) 60 daysThe question was posed to me in a job interview.Origin of the question is Intravascular Oximeters in division Oximeters of Biomedical Instrumentation |
|
Answer» Right answer is (C) 120 days |
|
| 56. |
1 f/l = ____(a) 10^18(b) 10^15(c) 10^-18(d) 10^-15The question was asked in homework.This intriguing question comes from Intravascular Oximeters in division Oximeters of Biomedical Instrumentation |
|
Answer» The CORRECT CHOICE is (d) 10^-15 |
|
| 57. |
Portable pulse oximeters are useful for ______ whose oxygen levels may decrease at high altitude.(a) Athlete(b) Swimmer(c) Mountain climber(d) FisherThe question was asked in a job interview.Asked question is from Pulse Oximeter in chapter Oximeters of Biomedical Instrumentation |
|
Answer» Correct answer is (c) Mountain climber |
|
| 58. |
What is the range of Instantaneous beat to beat rate digitally displayed?(a) 0 to 50 bpm(b) 50 to 210 bpm(c) 210 to 350 bpm(d) 350 to 410 bpmThis question was posed to me in an interview.Question is taken from Ear Oximeter topic in portion Oximeters of Biomedical Instrumentation |
|
Answer» The correct answer is (b) 50 to 210 BPM |
|
| 59. |
Blood flow detectors based on Doppler shift start detecting foetal pulses as early as in which week of pregnancy?(a) tenth(b) eleventh(c) twelfth(d) ninthI have been asked this question at a job interview.Query is from Oximeters in portion Oximeters of Biomedical Instrumentation |
|
Answer» CORRECT option is (b) eleventh For explanation: Blood flow detectors based on ultrasonic Doppler shift can detect foetal pulse as early as the tenth WEEK of pregnancy and in nearly all cases by the twelfth week. At about 20 weeks it is possible to detect multiple pregnancies especially if two instruments are used together and the pulse RATES compared. Intrauterine DEATH of the foetus can also be diagnosed. |
|
| 60. |
In phasing, if the cholesterol stream arrives at Y time, albumin must arrive at ______(a) Y + 5 s(b) Y + 10 s(c) Y + 15 s(d) Y + 20 sThis question was posed to me in a job interview.My question is based upon Skin Reflectance Oximeters topic in portion Oximeters of Biomedical Instrumentation |
|
Answer» Right answer is (c) Y + 15 s |
|
| 61. |
Which of the following is not the method of cell counting?(a) Microscopic method(b) Electrical conductivity method(c) Automatic optical method(d) Electroscopic methodThis question was addressed to me during an interview.This key question is from Intravascular Oximeters topic in section Oximeters of Biomedical Instrumentation |
|
Answer» Correct option is (d) Electroscopic method |
|
| 62. |
The transmitting crystal emits 40° divergent beam so that the beam covers an area of approximately _____ cm diameter.(a) 10(b) 20(c) 30(d) 40I had been asked this question in an interview for job.This question is from Oximeters topic in division Oximeters of Biomedical Instrumentation |
|
Answer» Correct option is (a) 10 |
|
| 63. |
Which of the following is not the part of the manifold?(a) Transmission tubing(b) Pump tubes(c) Platter(d) Plastic tubesThe question was posed to me in an internship interview.The origin of the question is Skin Reflectance Oximeters topic in section Oximeters of Biomedical Instrumentation |
|
Answer» Right choice is (d) Plastic tubes |
|
| 64. |
What is maximum ultrasound intensity of narrow beam transducer?(a) 15 mW/cm^2(b) 20 mW/cm^2(c) 25 mW/cm^2(d) 30 mW/cm^2I got this question during an internship interview.Origin of the question is Oximeters topic in division Oximeters of Biomedical Instrumentation |
|
Answer» The CORRECT answer is (c) 25 mW/cm^2 |
|